DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-341BRI-SET, ASAI-ADJ, BRI-DAT
9
m. Certain ISDN-BRI cause codes are logged by switch software. The cause
code can be determined from the following formula:
If the error type is greater than 3968, then the ISDN-BRI cause code is
equal to the error type minus 3968. This code was sent to the endpoint by
the switch.
If the error type is less than 3968, then the ISDN-BRI cause code is equal
to the error type minus 3840. This code was sent to the switch by the
endpoint.
A description of the various ISDN-BRI cause values is contained in Ta b l e
9-150. This table also contains recommended system technician actions
associated with the cause value. Further information can also be found in
the Lucent ISDN-BRI Specification (801-802-100). In addition, the Aux
Data field of the Error Log entry contains additional diagnostic information.
n. Error 3847 indicates that sets on the port do not support level 3
initialization. Consult the Set Service documentation
o. For the Error 2567 indicates that the version of ASAI is not supported,
check version of the software running on the ASAI or Lucent adjunct.
87 Internal switch
audit
There is an inconsistency in switch data
records.
1. There is no action needed since the
switch has corrected the data
inconsistency.
2. If a number of these errors continue to
occur, then escalate to next tier.
Table 9-149. ASAI CAUSE VALUES — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page