Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1053MET-LINE (MET Line)
9
MET Line Station Audits Test (#61)
This is a series of three tests that are classified as audits. These audits will abort
if attempted on an out-of-service station. Although this test will never actually
return a fail result (except for the internal system error), it is possible that it will
enter error types 257 (over current) or 513 (open circuit) into the error log. To
determine if there are any problems that do not show up in the test result, look for
these error types in the error log. If these errors appear in the error log or if user
complaints still exist, investigate by using other circuit pack tests and by
examining the station, the wiring, and the connections. The tests are as follows:
Switchhook Audit This is an update of the SPE records according to the
circuit packs’ records.
Bad Scan Inquiry A message is sent uplink that contains a count that is
generated due to certain events relating to the link
conditions. This is an indication of data transmission
problems between the MET Line circuit pack and the
voice terminal.
EPF Inquiry The status of the Electronic Power Feed is sent uplink.
Possible conditions are: EPF-on-ok, EPF-off, EPF-no-load,
and EPF-on-overcurrent.
Table 9-418. TEST #61 MET Line Station Audits Test
Error
Code
Tes t
Result Description/ Recommendation
ABORT Internal system error
1 ABORT The test was aborted due to an internal system error during the switchhook
audit.
2 The test was aborted due to an internal system error during the bad scan
inquiry.
3 The test was aborted due to an internal system error during the EPF audit
inquiry.
1. Make sure that the station is not in an out-of-service state.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page