9-109ANN-BD (Announcement Circuit Pack)
9
Table 9-41. TEST #210 140AY Looparound Test
Error
Code
Te s t
Result Description/Recommendation
1-3 ABORT Response to the test request was not received within the allowable time
period. The error code indicates at which speech compression rate the test
aborted (1 being the first rate tested, 3 being the last).
1. Retry the command at 1-minute intervals for a maximum of 5 times.
10 ABORT The Playback Speech Memory Array (PSMA) Test (#206) failed on
Announcement Port 1.
90 ABORT The Playback Speech Memory Array (PSMA) Test (#206) failed on
Announcement Port 9.
1. Refer to “ANN-PT”, Test #206.
1000 ABORT System resources required to run this test are not available. This test needs
Announcement Ports 1 and 9 to run. One of the ports may be in use on a
valid call.
If Ports 1 and 9 are not in use, retry the command at 1-minute intervals for a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.
1007 ABORT The announcement circuit pack thinks that Port 1 or Port 9 is busy.
1024 ABORT Announcement circuit pack blocked the test because an announcement
download is in progress. If a download is in progress, a status data-module
announcement data extension command should show that the
announcement data port is connected to a data line port that is part of a
system access port, and the tape drive should be active (to determine the
extension of the announcement data module, use the list data-module
command). See the ‘‘Locked Announcement Circuit Pack’’
at the end of the
table for Test #209.
1. Wait until download is finished (up to 45 minutes), and then run the test
again.