DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1879UDS1-BD (UDS1 Interface Circuit Pack)
9
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information specified by
System Administration to the UDS1 Interface circuit pack. Translation includes
the following data administered for a UDS1 Interface circuit pack (see output of
display ds1 UUCSS
command): DS1 Link Length between two DS1 endpoints,
Synchronization Source Control, All Zero Suppression, Framing Mode, Signaling
Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.
In G3V3, if a TN464F or later UDS1 circuit pack is combined with an Lucent
120A1 CSU Module to form and Integrated CSU Module, this test will also send
the administration for this Integrated CSU to the circuit pack to assure the
board’s translations are correct. The administration of the CSU Module is done
using the DS1 circuit pack administration form. Translation for the CSU Module
includes the following data: Transmit LBO, Receive ALBO, Supply CPE
Loopback Jack Power, etc.
Table 9-695. TEST #146 Translation Update Test
Error
Code
Tes t
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute interval s a maximum of 5 times.
FAIL Internal system software error.
1. Enter the display ds1 UUCSS command to verify the UDS1 Interface
circuit pack translation.
PASS Translation data has been downloaded to the UDS1 Interface circuit pack
successfully.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.