A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-152list sys-link
8
Feature Interactions
None.
list sys-link
list sys-link [print | schedule]
The list sys-link displays all of the system links. The location, link type and
channel number, link state, current path status, faulted path status, and last
recorded fault, if any, are displayed for each system link. See SYS-LINK in
Chapter 9, ‘‘ABRI-PORT (ASAI ISDN-BRI Port)’’
for details.
Output
Location
The physical location of the far endpoint associated with the system
link (cabinet-carrier-slot-circuit).
Link
Type/Channel
The type of system-link and the processor channel number of the link
(if there is one). System links include the following (see MO
SYS-LINK):
Expansion Archangel Links (EAL), Indirect Neighbor Links (INL),
Processor Gate Control links (PGC), PRI signaling links (PRI), System
Port links (SAP), Remote Neighbor links (RNL), Local Neighbor links
(LNL), X25 adjunct links. Processor channel numbers range from 1
to 128.
State
Whether the system link is “up” or “down.”
Current Path
This field specifies the status of the current path. This field displays
“none” if the link is down or “present” if the current path is functional.
Faulted Path
This field shows whether the link has experienced a fault and been
switched to another path. “Present” indicates that the link has been
faulted at least once. “None” is displayed if the link has not gone
down. “Default” is displayed if the default faulted path is being used.
Last Fault
Recorded
The date and time that the most recent fault on the link took place.