DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-765ETH-PT (Control LAN Ethernet)
9
b.
Error Type 513
: Link Integrity Inquiry Test (#1282) failed or CLAN port
detected loss of Ethernet link integrity.
Possible causes:
Cabling
Ethernet transceiver
1. Test the port (
test port UUCSSpp long).
c. Error Type 769
: Port received invalid frame.
Invalid Ethernet frame errors occur when the frame
contains a bad Cyclic Redundancy Check (CRC)
is misaligned
1. Isolate the problem with the Ethernet Local Looparound Test
(#1278).
2. Test the port (
test port UUCSSpp long).
3. Verify the repair with the Ethernet Local Looparound Test (#1278).
4. Clear the alarm (test port UUCSSpp long clear
).
d.
Error Type 1281
: System software received an indication that the far-end
has requested a disconnect of a session on this link. This is a log-only
error.
e.
Error Type 1537-1538
: Some or all sessions on a port are down.
f.
Error Type 1793-1920
: system software received an indication that a
socket was closed due to an error. Error Type indicates the application f
the application associated with this socket.
Aux Data indicates the internal application number.
If the switch: Then it:
Receives threshold failure rate Raises WARNING alarm
If: Then the switch:
Some sessions are down Raises WARNING alarm on circuit pack
All sessions are down Raises MINOR alarm on circuit pack
Error Type Application
1794 DCS
1795 AUDIX
1796 CMS
1797 ISDN Gateway