
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1932WAE-PORT (Wideband Access Endpoint Port)
9
Notes:
a. The wideband access endpoint has been busied out by a
busyout
access-endpoint
extension command. No calls can be made to this
extension.
b. The circuit pack has been removed or has been insane for more than
11-minutes. To clear the error, reinsert or replace the circuit pack.
c. The Conference Circuit Test (#7) failed on this port. See Test #7 for repair
procedures.
d. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for repair
procedures.
e. The TN464C UDS1 Interface circuit pack has failed. See UDS1-BD.
f. The Port Audit and Update Test (#36) failed due to an internal system
error. Enter
status access-endpoint
extension and verify the status of the
port. If the wideband access endpoint port is out of service, enter
release
access-endpoint
extension to put it back into service. Retry the test
command.
Technician-Demand Tests: Descriptions and Error
Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
NPE
Crosstalk Test
, for example, you may also clear errors generated from other tests
in the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Port Audit and Update Test (#36) X X ND