DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-887GPTD-PT (General Purpose Tone Detector Port)
9
Notes:
a. A Major or a Minor alarm may be logged with this error. A Major alarm is
raised when the total number of GPTD ports currently in service is less
than or equal to 1/2 of the threshold number administered via the
change
system-parameters maintenance
command. Otherwise a Minor alarm is
raised. In either case, run the Short Test Sequence on the alarmed GPTD
port and follow procedures for the individual test results.
b. The GPTD port lost its translation. Testing the GPTD port is sufficient to
reload its translation. If testing the GPTD port does not clear the error, then
replace the Tone Detector circuit pack containing the defective GPTD
port.
c. This error indicates the GPTD port is having problems detecting call
progress tones. If this error is logged constantly, replace the Tone Detector
circuit pack containing the defective GPTD port.
d. This Error Type indicates that the circuit pack has been removed or has
been insane for at least 11 minutes. To clear the error, reinsert or replace
the circuit pack.
257 (b) 17666 Tone Detector
Audit/ Update Test
(#43
MAJOR/
MINOR (a)
ON test port UUCSSpp r 3
513 (c) Any Tone Detection
Verification Test
(#42
MAJOR/
MINOR (a)
ON test port UUCSSpp r 3
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Table 9-337. General Purpose Tone Detector Port (CPTR) Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page