DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Additional Maintenance Procedures
6-8Software updates
6
Table 6-2. Software Update—Duplicated SPE
Step
Time
(min) Remarks
change sys-par maint
2 Note the current settings of the Save
Translation, SPE Interchange, and Alarm
Origination Activated fields and then set
them to n. Set CPE Alarm Activation Level
to
none
. Make sure scheduled daily
maintenance is not set to run during the
update.
save announcements
40 These steps create a backup tape in case
the update fails and a backout is
necessary. Saving announcements may
be skipped if
display announcements
shows no administered announcements.
save translation
2
backup disk
10
Remove tapes and
clean tape drives.
5 This procedure is described under
‘‘TAPE’’
in
Chapter 9, ‘‘Maintenance Object
Repair Procedures’’.
Insert the tapes
containing the new
software
2 Wait for the tape to retension itself.
list config
software-version long
5 Make sure the tapes have the expected
version number.
restore disk install
both
10 Copies new tape files to disk. If updating
from
a load earlier than 6.0, substitute for
this step the following sequence:
copy
announce tape
,
save translation tape
,
then
restore disk full both
.
Continued on next page