DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-373upgrade software
8
Command History Log
Unlike other commands, the upgrade software command is logged into the
history log
before
it completes, prior to the save translation step. A record of the
upgrade is saved on the new active SPE.
Alarm Origination
To prevent reporting of alarms generated by the upgrade, alarm origination is
suspended during the execution of the command. After a successful interchange
on a system with duplicated SPE, alarm origination remains suspended for
approximately 5 minutes, or until the newly active SPE is ready to begin normal
maintenance.
Enable All
All previously disabled maintenance objects are re-enabled following the
upgrade. If the command is canceled, disables are preserved.
Parameters
Output
The following display shows a typical result when
busyout ds1-facility 2e1a
is
entered.
For more information see the following sections at the beginning of this chapter:
‘‘Busyout and Release Commands’’
and ‘‘Common Output Fields’’.
UUCSSf
The location of a DS1 Converter facility. F represents a letter (a-d) used to
identify the separate DS1 facilities connected to the DS1 Converter.
override
This option must be used to busyout the facility on a DS1 Converter that is
carrying the packet traffic and control messages. See the caution note
above.
Port
The DS1 facility as described above in UUCSSf.
busyout ds1-facility 02e01a
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
02E01A DS1-FAC PASS
Command successfully completed