
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1466SNI-BD (SNI Circuit Pack)
9
active SNC and the SPE, an attempt will be made to reset the SNI via its
neighbor.
An SNI should be reset instead of reseating the circuit pack. The
reset board
command should almost never be used on an SNI. It may be necessary to use
the
reset board
command if the SNI circuit pack gets into a mode where it
cannot communicate with software.
If an SNI with active errors and alarms is reset, the errors and alarms may take a
while to come back, therefore the
reset board
command can mask real
problems.
Table 9-563. TEST #761 Switch Node Interface Reset Test
Error
Code
Tes t
Result Description/ Recommendation
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2302 ABORT Software received incorrect message data from the SNI circuit pack.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2303 ABORT The SNI circuit pack responded that the software test requested is invalid.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2304 ABORT SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page