9-1424SNC-REF (Switch Node Clock Reference)
9
Error Log Entries and Test to Clear Value
Notes:
a. This error occurs whenever the active or standby SNC detects problems in
its timing reference with an SNI circuit pack in the same carrier. The slot
location of the SNI with which the SNC cannot communicate is given in the
error table above.
If duplicated SNCs exist in the carrier:
1. If the SNCs are duplicated in the carrier, check the error log via
display errors. If both SNCs have this error, replace the SNI that
the SNCs are complaining about.
Table 9-557. SNC Reference Error Log Entries
Error
Type
Aux
Data
SNI
Slot
1
1. The slot location of the SNI with which the SNC cannot communicate.
Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
2
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test board UUCSS r 1
1(a) Any 2 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
257(a) Any 3 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
513(a) Any 4 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
769(a) Any 5 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
1025(a) Any 6 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
1281(a) Any 7 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
1537(a) Any 8 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
1793(a) Any 9 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
2049(a) Any 13 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
2305(a) Any 14 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
2561(a) Any 15 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
2817(a) Any 16 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
3073(a) Any 17 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
3329(a) Any 18 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
3585(a) Any 19 Failure Audit (#777) MAJOR OFF test board UUCSS r 1
3841(a) Any 20 Failure Audit (#777) MAJOR OFF test board UUCSS r 1