DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-930INADS (INADS Link)
9
6 0 INADS did not send the acknowledgment message to the ‘‘test inads alarm’’
message.
1. Verify that the INADS phone number and switch product id are correct via
the Maintenance-Related System Parameters Form.
2. Verify INADS is up and running.
3. Retry the command.
7 0 INADS sent a negative acknowledgment to the ‘‘TESTING INADS LINK’’
message.
1. Verify that the product id on the switch and in the INADS database are the
same. Use the Maintenance-Related System Parameters Form to
determine the product id the switch has.
2. Rerun the test.
8 0 Internal system error; system received an invalid return code.
9 0 Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
10 0 There is already a test inads-link command in progress.
1. Wait 10 minutes for the present command to finish.
2. Review the results of the present command by viewing the Error Log and
selecting the category ‘‘inads-link.’’
11 0 The switch is trying to report alarms to INADS. The test cannot be run at this
time.
1. Wait 10 minutes and retry the command.
Table 9-357. INADS Link Test Error Log Entries — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page