DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-147list measurements ds1
8
The following field descriptions pertain to the detailed reports accessed by the
list measurements ds1-log
and
list measurements ds1-facility log
commands.
Failed Seconds
The value of the failed seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if
the data for the 15-minute interval is invalid.
Worst 15-Min
Interval
The date(Date), end time(Time), and error count (Count; from 0 to
900 in increments of four) of the 15-minute interval in the previous
24-hour period that contains the maximum value for each of the
four error categories (errored seconds, bursty errored seconds,
severely errored seconds, and failed seconds).
Total of 24-Hour
Count
The sum of all valid 15-minute counts for the previous 24-hour
period for each of the four error categories. This field has a value
from 0 to 65535.
Current
15-Minute
Interval
The error count for the current (incomplete) 15-minute interval for
each of the four error categories. This field has a value from 0 to
899 or N/A if the data for the current 15-minute interval is invalid.
Counted
Since:
The start time and date when the associated measurement counters
were cleared or the DS1C circuit pack was administered.
Date
The date of the 15-minute interval.
Time
The time of the 15-minute interval.
Errored
seconds
The value of the errored seconds counter for the specified 15-minute
interval. This field has a value from 0 to 900 or N/A if the data for the
15-minute interval is invalid.
Bursty err
secs
The value of the bursty errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if the data
for the 15-minute interval is invalid.
Valid
interval
This field indicates whether the data for the specified 15-minute interval
is valid. Data is considered valid when a count for that 15-minute
interval. If the field has a value of ‘‘y’’, the data for the four error
categories is valid; otherwise, the data is invalid. Data is considered
valid when a count for that 15-minute interval is retrieved and none of the
following invalid conditions occur. Data is invalid if a system warm start
or a system cold start occurred during the interval, if the DS1C circuit
pack was not inserted during the interval, if the system time was
changed during the interval, or if the system was too busy to respond to
a poll request for the interval.