Maintenance Object Repair Procedures
9-192ATM-EI (Expansion Interface Circuit Pack)
9
Expansion Interface Lock Query Test (#304)
This test is non-destructive and is used to query the ATM and EI circuit packs
(both active and standby) for its status concerning lock to the backplane system
clock. It is run as part of periodic, scheduled, initialization, and error analysis
40MM FAIL Failure code only applies to a system equipped with an ATM Switch. The
letters “MM” refer to the distant or far-end port network (PN), and “NN” to the
near-end ATM-EI under test.
The test failed for the first connection from the ATM-EI board under test to
another EPN, and the test tone was detected correctly in the reverse
direction (data sent from the MM port network was detected correctly in the
port network in which the circuit pack under test resides), but not the
opposite direction.
1. Test for the Active Tone-Clocks on the MM PN and the PN in which the
ATM-EI under test resides. This determines if dial tone is supplied.
2. Ensure that the ATM address of the active ATM-EI circuit pack in port
network MM matches the ATM address on the ATM switch for the port to
which this circuit pack is connected. Refer to the ‘‘ATM Tips’’
section in
Chapter 5 for the procedure to check the ATM port address on the ATM
switch.
3. Run this Test #241 on the active ATM-EI in port network MM. If this test
fails with Error Code 20NN or 40NN, go back to Step 2.
If the address was the same, replace the active ATM-EI circuit pack on
port network MM.
If this test fails with Error Code 10NN or 30NN, replace ATM-EI circuit
pack with the initial problem.
PASS Tone successfully transmitted in both directions. Both ATM-EI boards and
their lightwave transceivers are functioning properly.
0NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 9-80. Expansion Interface 2-way Transmission Test (#241) — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page