A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-331test ds1-loop
8
Parameters
location
A [location] represents the physical position of the
board to be tested. For Standard cabinets a location is
entered as [UUcSS] where “UU” represents the
cabinet number, “c” represents the carrier, and “SS”
represents the slot position. A single digit cabinet
(1-3) are entered with or without a leading zero (0).
cpe-loopback-jack-test-begin
1
1. The test will abort if the busyout command has not been set
For TN464F or TN767E or later suffix DS1 boards, this
causes a long-duration loopback test to be setup
through the Customer Premises Equipment (CPE)
Loopback Jack. The command allows you to specify a
loop-up code for the CPE loopback jack if it differs
from the default of 0x47F. Specify the number of bits in
the loop-up code as well as the actual bit-pattern (in
hexadecimal).
far-csu-loopback-test-begin
1
For TN464F or TN767E or later suffix DS1 boards, this
causes a long-duration loopback test to be setup
through the far-end Channel Service Unit (CSU).
one-way-span-test-begin
1
For TN464F or TN767E or later suffix DS1 boards, this
begins execution of a long-duration one-way span
test.
end-loopback/span-test
For TN464F or TN767E or later suffix DS1 boards, this
parameter terminates long-duration one-way span and
loopback testing.
inject-single-bit-error
For TN464F or TN767E or later suffix DS1 boards, this
parameter causes a single bit error to be sent within
an active framed 3-in-24 test pattern used in
long-duration loopback and span testing.
ds1/csu-loopback-tests
For TN464F or TN767E or later suffix DS1 boards, this
parameter executes the following loopback tests: DS1
Board LoopBack, CSU Module Equipment LoopBack,
and CSU Module Repeater LoopBack. These tests are
performed sequentially for a short duration each, and
individual PASS/FAIL/ABORT test results are reported
following each test.