
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1611SYSAM (Circuit Pack)
9
Time-Of-Day Clock Test (#913)
The short term accuracy of the time-of-day clock is tested. The test reads the
clock once, waits 10 seconds, and then reads the clock again. The second
reading of the clock must be within certain limits (10 seconds) relative to the first
reading for the test to pass. The
display time
command can be used to display
the current setting of the time-of-day clock.
If the time-of-day clock is not functioning correctly, the software time-of-day clock
is used (this clock is not as accurate as the hardware clock).
FAIL Internal System Error
1. Retry the command
PASS The SYSAM circuit pack has been sent the correct state for the system LEDs.
If the LEDs do not reflect the system alarms shown in the alarm log, the
SYSAM circuit pack may have problems.
1. Verify the LEDs on the SYSAM circuit pack can be changed by issuing
the test led port-network 1 command. All the SYSAM circuit pack LEDs
should go on and then off, and then be refreshed.
2. After the test led port-network 1 command finishes, if the SYSAM circuit
pack LEDs do not reflect the alarm log, follow normal escalation
procedures.
Table 9-609. Test #913 Time-Of-Day Clock Test
Error
Code
Te st
Result Description/ Recommendation
100 ABORT The requested test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
Continued on next page
Table 9-608. Test #912 SYSAM Refresh Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page