DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-120ANN-PT (Announcement Port)
9
2. Performing a
test board long
when the circuit pack is in this state will
yield the following abort codes:
■ Ports 1 AND 9 abort Test 206 with code 1024.
■ Ports 1 AND 9 abort Test 205 with code 2000.
■ Board level Tests 209 and 210 abort with code 1024.
3. The
save/restore announcements
command will time out with:
Error encountered, can’t complete request
The Announcement circuit pack lock-up can be cleared remotely by performing
a soft reset to the circuit pack:
■ busy-out board UUCSS
(this command drops all calls in progress on the
Announcement circuit pack).
■ Reset circuit pack using the
reset board UUCSS
command.
■ Release board using the
release board UUCSS
command.