A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1308PNC-DUP (PNC Duplication)
9
i. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
EAL. This indicates that one or more Expansion Archangel Links are down.
Investigate any EXP-PN alarms. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(11003 points to port network 4.)
List config port-network
gives the
cabinet number associated with a port network.
j. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
INL. This indicates that one or more neighbor or indirect neighbor links
with an EI as an endpoint have experienced faults. Investigate any alarms
against EXP-PN and SN-CONF. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(11103 points to port network 4.)
List config port-network
gives the
cabinet number associated with a port network.
k. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
HW. This indicates that one or more neighbor or indirect neighbor links
with an EI as an endpoint have experienced faults. Investigate any alarms
against EXP-PN and SN-CONF. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(11203 points to port network 4.)
List config port-network
gives the
cabinet number associated with a port network.
l. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
PER. This indicates one or more faults on peer links that connect SNIs to
EIs. Investigate any alarms against SNI-PEER. Adding 1 to the last two
digits of the error code gives the PN number of the port network that
reported the alarm. (11303 points to port network 4.)
List config
port-network
gives the cabinet number associated with a port network.
m. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
DS1. This indicates faults on one or more DS1C facilities. Investigate any
alarms against DS1-FAC. Adding 1 to the last two digits of the error code
gives the PN number of the port network that reported the alarm. (11403
points to port network 4.)
List config port-network
gives the cabinet
number associated with a port network.
n. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
SNIL. This indicates one or more faults on peer or neighbor links between
SNIs on different switch nodes. Investigate any alarms against SNI-PEER.
The last two digits of the error code indicate the fiber-link number (01-27)
of the fiber that reported the retired alarm. List fiber-link gives the
location of the fiber.
o. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
SNIHW. This indicates one or more faults on hardware connecting SNIs on