A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1690TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
9
Layer 3 Query Test (#1243)
This test is nondestructive.
This test is used to check the application layer communications across the
in-service ISDN D-Channel. The test passes if a status enquiry message is
successfully sent, fails if the signaling link is down, and aborts if a query is
already running or there is an internal error.
4 FAIL Received a status of Level 1 Pending Activation, the NT1 has a loss of
power indicating a problem with the NT1.
1. Follow the manufacturer-recommended repair procedures for the NT1.
2. Execute the test port UUCSSpp command and review the results of
the Level 1 Status Inquiry test to verify the repair.
PASS This test indicates that Level 1 is activated or that software has taken the
port out of service.
Table I-3. TEST #1243 Layer 3 Query
Error
Code
Te st
Result Description/ Recommendation
1019 ABORT Test is already running.
1113 ABORT The signaling link is down.
1. Use the test port UUCSSpp long command to clear any errors which
prevent establishment of the signaling link.
2. Examine the results of Test #626, which is executed with the
command. If this test aborts or fails, follow the repair procedure for the
Signaling Link Status Test.
3. Escalate problem if BRI Layer 3 Query Test continues to abort.
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long UUCSSpp
command and review the results of the BRI Port Local LAN
Looparound Test to verify the repair.
Continued on next page
Table 9-635. TEST #1242 Level 1 Status Inquiry — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page