DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Initialization and Recovery
4-13SPE-Down Command Interface
4
The following qualifier can be used with the test commands:
Enter
only
the characters which appear in bold type. For instance, to test all
memory boards ten times, enter t ma 10 Entering t results in testing all boards
once. You can abort the execution of a command by pressing
ESC 3 times.
Test Commands
After a command is entered, various test result messages are printed on the
terminal, indicating whether each test passes, fails or aborts. If any components
fail, refer to the Maintenance Object documentation that applies. Additional
information for interpreting these results can be found in the ‘‘Troubleshooting a
Table 4-2. SPE-Down Interface Commands
Keyboard Entry Command
?
Help
r
Reboot
s
Secondary reboot
d
display alarms
t al
or
t
Test all standby SPE circuit packs
t sy
Test SYSAM circuit pack
t pr
Test Processor circuit pack
t m1
Test Memory circuit pack 1
t m2
Test Memory circuit pack 2
t m3
Test Memory circuit pack 3
t m4
Test Memory circuit pack 4
t ma
Test all Memory circuit packs
t du
Test DUPINT circuit pack
t ms
Test MSSNET circuit pack
t p1
Test PKTINT circuit pack 1
t p2
Test PKTINT circuit pack 2
t p3
Test PKTINT circuit pack 3
t pa
Test all PKTINT circuit packs
1
to
99
Number of repetitions (default is 1)