A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1492SPE-SELE (SPE Select Switch)
9
Figure 9-88. Duplication Interface Circuit Pack
Error Log Entries and Test to Clear Values
Notes:
a. Error 1 appears when one SPE Select Switch is in the AUTO position and
the other is in the select A or select B position. Placing both switches in
the AUTO position will retire the alarm immediately.
b. Error 257 appears when both SPE Select Switches are in the select A or
select B position for more that 6 hours. Placing both switches in the AUTO
position will retire the alarm immediately.
Table 9-568. SPE Select Switch Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Check the position of the SPE-Select switches.
0 Any Any Any
1(a) 0 none WARNING OFF
257(b) 0 none MAJOR OFF
SPE-Select Switch
SPE-Select LED (Red)
Alarm LED (Red)
Test LED (Green)
Busy LED (Yellow)
O
O
O
SPE
AUTO
Override
B A
O
O