DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-320test alarms
8
Error Messages
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Query From Input
After entering the command
test alarms
, the system technician will be presented
with an options form for alarm selection.
Alarm
Types
The type of alarm to be tested is specified by placing a ’y’ or ’n’ in the
alarm type fields. The technician can choose a combination of active
alarms: major, minor, and/or warning.
Interval
Test alarms for records for the last hour (h), last day (d), last week (w) or
all (a). The default is all.
From
Test alarm associated with records from the time specified by
mm/dd/hh/mm, where mm month, dd is the day, hh is the hour and mm is
the minute. If no “from” date is entered, then no checking is done. This will
give the user all the alarms active since a month prior to the current time.
To
Test alarms associated with records to the time specified by
mm/dd/hh/mm, where mm is the month, dd is the day, hh is the hour and
mm is the minute. If no "to" date is entered, any alarm which is active after
the from date will be selected.