DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-172ATM-EI (Expansion Interface Circuit Pack)
9
Notes:
a. Error Type 2: on-board DUART chip failed. This results in communication
failure between the port network’s maintenance board and the ATM-EI
board. The Maintenance circuit pack should have a red LED lit, because
the link to the ATM-EI is down in this EPN.
1. Reset the board with the
reset board UUCSS
command.
2. If the board does not recover, replace the board.
b. Error Type 18: the ATM-EI circuit pack has been busied out.
1. Release the circuit pack (
release board UUCSS
).
c. Error Type 23: an ATM-EI circuit pack has been administered with the
add
atm-pnc
n
command, but the circuit pack has not been inserted into the
system.
1. Insert an ATM-EI circuit pack at this location.
d. Error Type 125: a wrong circuit pack is located in the slot where the
ATM-EI circuit pack is logically administered.
1. Either remove the wrong circuit pack and insert the ATM-EI circuit
pack or remove the ATM-EI administration (see ‘‘Basic ATM PNC
administration’’).
2. Remove the ATM-INTF administration and re-administer the slot
(change circuit-pack) to match the circuit-pack that is physically
present in this slot.
3841 (u)
3842 (v)
3999 (w) Any None
1. Aux Data 32767 for any error log entry indicates that an alarmed ATM-EI was busied out and then
released. When this occurs, existing service-affecting alarms must be preserved. Typically, all
alarms are resolved when the ATM-EI is released. Therefore, the Alarm and Error Logs must be
repopulated with the alarms present at time of busyout. This Error Code indicates that existing Aux
Data and Error Log time stamps are no longer valid because they were lost when the circuit pack
was released.
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
3. Test # 1258 applies to TN2238 (R6.3); Test #1293 applies to TN2305 and TN2306.
Table 9-74. ATM-EI Error Log Entries — Continued
Error
Type
Aux
Data
1
Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page