DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-40ALARM-PT (ALARM PORT)
9
ALARM-PT (ALARM PORT)
The Alarm Port MO provides on-board maintenance for an analog line port that is
administered as an external device alarm port. Test are provided to verify the
analog line ports ability to detect an external device alarm. The external device
alarm (EXT-DEV) MO is used for the off-board external device alarm.
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate errors.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
ALARM-PT MIN test port UUCSSpp l Alarm-Port
ALARM-PT WRN test port UUCSSpp sh Alarm-Port
Table 9-16. 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures
0 Any Any Any test port UUCSSpp sh r 1
15 (a) Any Audits and
Updates Test
(#36)
18 0 busy-out station
extension
WARN IN
G
OFF release station
extension
130 (b) None WARNIN
G
ON test port UUCSSpp sh
769 Battery Feed
Test (#35)
MINIOR ON test port UUCSSpp sh r 2