A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-519DIOD-DS1 (DS1 DIOD Trunk)
9
DIOD-DS1 (DS1 DIOD Trunk)
NOTE:
Many trunk problems are caused by incorrect settings of parameters on the
trunk group administration form. Settings must be compatible with the local
environment and with parameter settings on the far-end. Refer to
DEFINITY
Enterprise Communications Server Release 5.4 Administration and Feature
Description
, for information on how to administer trunks. The Application
Notes section of that book shows the correct settings for administrable
timers and other parameters on a country-by-country basis.
A DS1 DIOD trunk provides a link for digitized voice or data communications
between the system and a central office switch. There are two types of DS1
interfaces:
24 DS0 channels on a 1.544 Mbps link
31 DS0 channels + 1 framing channel on a 2.048 Mbps link
32-channel mode is supported only on TN464 circuit packs and on G3r V2
systems.
The DS1-DIOD maintenance object monitors and maintains a DIOD trunk port on
a TN464 UDS1 Interface circuit pack. See "UDS1-BD (UDS1 Interface Circuit
Pack)" in this chapter for more information about this circuit pack. The DS1 circuit
pack supports low level CO trunk signaling interfaces for both ground-start and
loop-start trunks. This maintenance strategy covers the in-line errors log,
initialization tests, periodic tests, scheduled tests, demand tests, and alarm
resolution and escalation.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
DIOD-DS1 MAJOR
1
1. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by the
set options command and that at least 75 percent of the trunks in this trunk group are
alarmed. For more information on the set options command.
test trunk
group# member#
lDS1 DIOD Trunk
DIOD-DS1 MINOR test trunk
group# member#
lDS1 DIOD Trunk
DIOD-DS1 WARNING test trunk
group# member#
DS1 DIOD Trunk