A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-317test alarms
8
The following display shows a typical result when
status tti
is entered.
test alarms
This command tests the hardware associated with selected alarms
Synopsis
test alarms
auto-page failures step [short | long][repeat number | clear]
Permissions
The following default logins may execute this command: system technician,
inads, init, nms.
Examples
test alarms
test alarms step failures
test alarms long clear auto-page
test alarms long failures
Description
This command allows the technician to automatically test all of the hardware that
is associated with the active alarms in the alarm log. This command provides a
query form to help the user narrow the selection of alarmed objects. Once the
form is filled out, the user presses
ENTER and the hardware associated with the
selected alarm log entries is tested. The results will be displayed in standard test
output and status information will be displayed on the message line as the
command progresses.
Several alarms may be logged against a single maintenance object, each alarm
representing a different problem. Even if there are multiple entries in the alarm
status tti
TTI STATUS
TTI Background Task State: completed - all ports translated
TTI State: voice
# of Boards Completed: 30
# of Boards Left to Process: 0
Percent Complete: 100
Elapsed Time since Task Started: 0 :0 :1