A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-405CLSFY-PT (Call Classifier Port)
9
CLSFY-PT (Call Classifier Port)
The TN744 Call Classifier is a service circuit pack that provides specialized tone
detection capabilities to support the Outbound Call Management (OCM) and
Inbound Call Management (ICM) features. The TN744 supports both A-law and
Mu-law companding.
The TN744 has eight ports (CLSFY-PTs), each capable of supporting call
classification, touch-tone reception and MFC-tone generation and detection. The
CLSFY-PT maintenance object implements a set of tests designed to ensure
proper operation of the Call Classifier.
Error Log Entries and Test to Clear Values
Notes:
a. There are two possible alarm levels for this error type: MAJOR and
MINOR. A major alarm is raised if the total number of call classifier ports
currently in-service is less than or equal to 1/2 of the administered
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
CLSFY-PT
1
MAJOR test port UUCSSpp sh Call Classifier Port
CLSFY-PT MINOR test port UUCSSpp sh Call Classifier Port
CLSFY-PT WARNING test port UUCSSpp sh Call Classifier Port
Table 9-171. Call Classifier Port (CLSFY-PT) Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1 any Tone Detector
Audit/Update Test (#43)
MAJOR/
MINOR(a)
ON test port UUCSSpp r 2
18 busyout port WARNING OFF release port UUCSSpp
257(b) 17666 Tone Detection Audit
Update Test (#43)
MAJOR/
MINOR(a)
ON test port UUCSSpp r 3
513(c) any Tone Detection Verification
Test (#42)
MAJOR/
MINOR(a)
ON test port UUCSSpp r 3