9-1444SNI-BD (SNI Circuit Pack)
9
106 FAIL The SNI circuit pack cannot communicate with the SNI in slot 6 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 6. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 1025. If other SNI circuit packs have SNI-PEER error
type 1025, then replace the SNI in slot 6. Replacing an SNI may be service
interrupting. Refer to the SNI-BD section for the procedure for replacing an
SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 1025 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 6.
107 FAIL The SNI circuit pack cannot communicate with the SNI in slot 7 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 7. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 1281. If other SNI circuit packs have SNI-PEER error
type 1281, then replace the SNI in slot 7. Replacing an SNI may be service
interrupting. Refer to the SNI-BD section for the procedure for replacing an
SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 1281 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
1. Replace this SNI.
2. Replace the SNI in slot 7.
Table 9-559. TEST #755 SNI Circuit Path Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page