9-475DID-DS1 (Direct Inward Dial Trunk)
9
Maintenance does not start any testing or generate any alarms in
response to these errors.
b. Error Type 15
This is a software audit error that does not indicate any
hardware malfunction. Run Short Test Sequence and investigate errors (if
any).
c. Error Type 18
The trunk has been taken out of service by a demand
busyout. No calls can be made on this trunk.
d. Error Type 130
This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257
DS1 Interface circuit pack detects a hardware error on
the DS1 DID trunk. The Aux Data field indicate the source of the error:
f. Error Type 513
DS1 Interface circuit pack detects a hardware error on
the DS1 DID trunk. Aux Data 57392 indicates no external release on PBX
disconnect.
g. Error Type 769
DS1 Interface circuit pack detects a hardware error on
the DS1 DID trunk. Aux Data 57393 indicates belated external release on
PBX disconnect.
h. Error Type 1793
DS1 Interface circuit pack is out-of-service. Look for
DS1-BD/UDS1-BD errors in Hardware Error Log. Refer to the appropriate
“DS1-BD/UDS1-BD” information for details.
i. Error Type 2305—This error indicates that a signaling change was
detected by the PBX trunk circuit pack which is inconsistent with the
present state of the trunk.
j. Error Type 3840
Port Audit and Update Test (#36) failed due to an
internal system error. Enter
status trunk
command to verify the status of
the trunk. If the trunk is out-of-service, then enter the
release trunk
command to put it back to in-service. Retry the test command.
57474 Rotary dial rate above 12 pulses per second
57473 Rotary dial rate below 8 pulses per second