Maintenance Object Repair Procedures
9-1018MAPD-BD (MAPD Interface Circuit Pack TN802)
9
NPE Connection Audit Test (#50)
The system sends a message to the on-board microprocessor to update the
network connectivity translation for the SCOTCH-NPE chip on the circuit pack.
Table 9-392. System Technician-Demanded Tests
Order of Investigation
Apply to
TN802?
1
1. N = No; this test either passes or ABORTS with Error Code 2000 (problem with NT)
Short
Tes t
Sequence
Long Test
Sequence
Reset
Board
Sequence D/ND
2
2. D = Destructive; ND = Nondestructive
NPE Connection Audit Test (#50) Y X ND
Control Channel Loop Test (#52) Y X ND
Loss of Signal Alarm Inquiry Test
(#138)
NXX ND
Blue Alarm Inquiry Test (#139) N X X ND
Red Alarm Inquiry Test (#140) N X X ND
Yellow Alarm Inquiry Test (#141) N X X ND
Major Alarm Inquiry Test (#142) N X X ND
Minor Alarm Inquiry Test (#143) N X X ND
Slip Alarm Inquiry Test (#144) N X X ND
Misframe Alarm Inquiry Test (#145) N X X ND
Translation Update Test (#146) N X X ND
SAKI Sanity Test (#53) Y X D
Continued on next page
Table 9-393. TEST #50 NPE Connection Audit Test
Error
Code
Tes t
Result Description/ Recommendation
None
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1019 ABORT The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page