A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1331PPP-PT (Control LAN Packet/Port)
9
TCP/IP Ping Test (#1281)
This non-destructive test fails if the endpoint fails to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board UUCSS
and reset board UUCSS).
2. If the problem persists, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2100 ABORT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
FAIL CLAN circuit pack detected test failure.
1. If the problem persists, reset the circuit pack (busyout board UUCSS
and reset board UUCSS).
2. If the problem persists, replace the circuit pack.
PASS Port circuitry functioning properly.
Table 9-520. TEST #1281 TCP/IP Ping Test
Error
Code
Te st
Result Description/ Recommendation
1, 2 ABORT Internal error
1. Retry the command at 1-minute intervals a maximum of 3 times
7 ABORT Destination unreachable.
1. Verify that at least one destination reachable through this port is up.
Once verified, test the port again (test port UUCSS) verify that the
TCP/IP Ping Test (#1281) passes.
Continued on next page
Table 9-519. TEST #1275 SCOTCH Synchronous Looparound Test — Continued
Error
Code
Te st
Result Description/ Recommendation
Continued on next page