
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-338test environment
8
test environment
test environment UU [short | long] [repeat # | clear] [schedule]
The
test environment
command performs hardware diagnostic tests of the
environment monitoring and control, and emergency transfer functions of a
specified cabinet. This command tests both PPN and EPN cabinets. Circuit
packs involved are the SYSAM (PPN) EPN Maintenance, and tone/clock (for the
ring generator test.
!
CAUTION:
The
long
test recycles power on all port circuit pack carriers and is
destructive. It does not recycle power on active or standby PPN or EPN
control carriers or switch node carriers. When a port carrier is recycled, all
service and links to ports on the carrier are dropped. If a carrier containing
an active EI or tone-clock is recycled, all service to that cabinet will be
disrupted.
There are nine Maintenance Objects involved in this test:
Note that although the CUST-ALARM maintenance object is part of the
environment functionality, it is not actually tested using the ‘test maintenance’
command. See ‘test customer-alarm’ for details on testing this particular MO.
Output
The following display shows a typical result when test environment 1 is entered
in order to test the PPN cabinet.
Error Code
A system-generated number that tells why the release failed or aborted.
A detailed list of the codes according to “Test No.” is provided for each
MO.
EMG-XFER POWER RING-GEN
AC-POWER DC-POWER CUST-ALARM
CARR-POW CABINET EXT-DEV