DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-289status processor-channel 1
8
The status pgate-port command displays the operational status of a a specified
Packet Gateway port. Such ports support the connection of X.25 adjunct
applications to the system. If the technician knows the X.25 link number
associated with the connection, but not the port number, then the “status link”
command may be used to access exactly the same information.
Adjunct Applications supported over X.25 connections include:
■ AUDIX
■ Calling Party Billing Number (CPN/BN or ISDN Gateway)
■ CMS
■ DCS
■ Gateway Channels for DCS over ISDN-PRI
■ Message Server
See
DEFINITY Communications System Generic 3 V2 Implementation,
555-230-653, for details. Status information provided by the command is
restricted to the switch hardware and extends no further than the Packet
Gateway circuit pack port.
The screen output for this command is the same as that for the
status link
command.
status processor-channel 1
The following screen applies to processor channels carried over link type of
Ethernet or ppp (using the TCP/IP protocol).
PROCESSOR CHANNEL STATUS
Channel Number: 1
Channel Status: Administered but not connected
Link Number: 3
Link Type: ethernet
Message Buffer Number: 0
Reset Count: 0
Retransmission Count: 0