DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-449CONFIG (System Configuration)
9
CONFIG (System Configuration)
The System Configuration maintenance object (MO) oversees logical insertion
and removal of circuit packs in the system. When Switch Control detects that a
circuit pack is present in a port slot, it informs System Configuration and System
Configuration queries the circuit pack to determine the type and vintage of the
circuit pack. Similarly, when Switch Control detects that a circuit pack has been
removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors
are logged to the Hardware Error Log.
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates that a port circuit pack in the system did not respond
to a circuit pack type inquiry. Follow the procedures outlined in (b) to
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a port circuit pack in the system did not respond
to a vintage inquiry.
As a result of either of these errors, a port circuit pack may be physically
inserted in a port slot, but the system may not recognize its existence. The
Aux Data field specifies the circuit pack’s port-network number as
indicated in the following table.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
CONFIG none none System Configuration
Table 9-187. System Configuration Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. This error should not occur. It indicates that an attempt was made by software to raise an alarm
against CONFIG without first logging a CONFIG error.
0 none none N/A none
1-119 (a) 0-21 none
257(b) none MAJOR
1001-111
9 (c)
0-21 none