DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-265ATM-TRK (Circuit Emulation Service Circuit Pack)
9
b. reset board UUCSS
c. test board UUCSS long
d. release board UUCSS
2. If the problem persists and there are no PKT-BUS or port alarms,
replace the circuit pack.
k. Error Type 1538: The ATM-TRK circuit pack is hyperactive (sending an
abnormal number of control messages to the processor). Use the
following command sequence for this ATM-TRK circuit pack:
1. busyout board UUCSS
2. reset board UUCSS
3. test board UUCSS long
4. release board UUCSS
5. If this error persists, replace the circuit pack.
l. Error Type 1794: LANHO transmit FIFO overflow. The circuit pack’s
transmit buffers have overflowed.
1. Run
test board UUCSS r 5
.
m. Error Type 2049: ACL Link Failure (link is down). The ATM Control Link
(ACL) has failed, communication has been interrupted between the SPE
and the ATM-TRK circuit packs on the system, and signaling-group
parameters are not communicated across the packet bus.
1. Check the PKT-BUS (Packet Bus)
and SYS-LINK (System Link)
maintenance objects, and follow the repair procedures indicated.
2. Run
test board UUCSS
against the ATM-TRK circuit pack.
n. Error Type 2306: too many parity errors in data received from the
LAN/packet bus.
If Then
Test #598 fails Replace the circuit pack.
If Then
Test 598 fails. Follow the repair procedures suggested for that
test.