A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1310PNC-DUP (PNC Duplication)
9
v. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the B-PNC associated with fault class FC_SNIHW. Use
status
pnc
to look at the state of health indexes for the PNCs, and investigate any
associated alarms. The last two digits of the error code indicate the
fiber-link number (01-27) of the fiber that reported the retired alarm.
List
fiber-link
gives the location of the fiber.
w. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the B-PNC associated with fault class FC_
EAL. This indicates that one or more Expansion Archangel Links are down.
Investigate any EXP-PN alarms. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(21003 points to port network 4.)
List config port-network
gives the
cabinet number associated with a port network.
x. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the B-PNC associated with fault class FC_
INL. This indicates that one or more neighbor or indirect neighbor links
with an EI as an endpoint have experienced faults. Investigate any alarms
against EXP-PN and SN-CONF. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(21103 points to port network 4.)
List config port-network
gives the
cabinet number associated with a port network.
y. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the B-PNC associated with fault class FC_
HW. This indicates that one or more neighbor or indirect neighbor links
with an EI as an endpoint have experienced faults. Investigate any alarms
against EXP-PN and SN-CONF. Adding 1 to the last two digits of the error
code gives the PN number of the port network that reported the alarm.
(21203 points to port network 4.)
List config port-network
gives the
cabinet number associated with a port network.
z. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the B-PNC associated with fault class FC_
PER. This indicates faults on peer links that connect SNIs to EIs.
Investigate any alarms against SNI-PEER. Adding 1 to the last two digits of
the error code gives the PN number of the port network that reported the
alarm. (21303 points to port network 4.)
List config port-network
gives
the cabinet number associated with a port network.
aa. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the B-PNC associated with fault class FC_
DS1. This indicates faults on one or more DS1C facilities. Investigate any
alarms against DS1-FAC. Adding 1 to the last two digits of the error code
gives the PN number of the port network that reported the alarm. (21403
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
ab. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the B-PNC associated with fault class FC_
SNIL. This indicates faults on peer or neighbor links between SNIs on