9-1078MODEM-BD (Modem Pool Circuit Pack)
9
If the MMI circuit pack that provides synchronization is craft busied out, it will not
affect the PN synchronization. The signal is still provided by the busied-out pack.
There is no affect on synchronization if the technician issues a release of the
busied-out MMI. Synchronization is not affected by a warm start of the system
(reset system 1). For all other restarts (reboot through cold 2), MMI
synchronization recovers during board insertion.
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes
There are no system technician-demanded tests for MMI-SYNC.
MODEM-BD (Modem Pool Circuit
Pack)
Refer to XXX-BD (Common Port Circuit Pack) for circuit pack level errors. See
also MODEM-PT (Modem Pool Port) for related port information.
Table 9-429. MMI-SYNC Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
1 Any None See note
1
1. An MMI synchronization switch was successful. Refer to MMI-BD errors for the reason for the
switch.
257 Any None MINOR OFF See note
2
2. The requested MMI synchronization switch failed. Resolve all MMI-BD alarms.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier designation
(A, B, C, D, or E).
SS
is the number of the slot in which the circuit pack resides (01 to 21).
Full Name of MO
MODEM-BD MIN test board UUCSS sh Modem Pool Circuit Pack
MODEM-BD WRN test board UUCSS sh Modem Pool Circuit Pack