A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1777TIME-DAY (Time of Day)
9
3. Test the active TN1648 SYSAM circuit pack using the
test maintenance [a
| b] sh
command. If any tests fail, refer to the repair procedures for the
SYSAM circuit pack before further investigating time-of-day problems. If
all tests PASS and the alarm has not been retired, proceed to Step 4.
4. Replace the active TN1648 SYSAM circuit pack must be replaced. See
"Replacing SPE Circuit Packs"
in Chapter 5. The alarm should be resolved
within 15 minutes of replacing the SYSAM and resetting the time with
set
time
.