Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1726TDM-CLK (TDM Bus Clock)
9
4. For Port Networks with more than one Tone-Clock circuit pack,
interchange Tone-Clocks with the
set tone-clock UUC
, then run
test synchronization r 10
, and check to see if new 2305 errors are
reported against the new active Tone-Clock circuit pack. If not,
replace the standby Tone-Clock circuit pack. See
How to Replace
the Tone-Clock Circuit Pack
in the TONE-BD section. If this clears
the error, the problem has been resolved.
5. Replace the EI circuit pack for the active PNC. In the direct-connect
case, use the
list fibers
command to identify which active EI
connects with the PPN.
6. If the problem is still not cleared, and the Tone-Clock circuit pack
reported in the error log has not been replaced up to now, replace
it. See
How to Replace the Tone-Clock Circuit Pack
in the TONE-BD
section.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
SAKI
Reset Test
for example, you may also clear errors generated from other tests in
the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence D/ND
1
SAKI Reset Test (#53) (a) X D
Clock Health Test (#46) (b) X X ND
Control Channel Looparound Test (#52)
(a)
XX ND
Tone Generator Crosstalk Test (#90) (c) X ND
Tone Generator Transmission Test (#40)
(c)
XX ND
Tone Generator Audit/Update Test (#41)
(c)
XX ND
TDM Bus Clock Circuit Status Inquiry
Test (#148)
XX ND
TDM Bus Clock Slip Inquiry Test
(#149)(e)
XX ND
TDM Bus Clock PPM Inquiry Test (#150) X X ND