DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1011MAPD-BD (MAPD Interface Circuit Pack TN802)
9
Error Log Entries and Test to Clear Values
Table 9-390. MAPD (TN802) Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test board UUCSS
1 (a) 0 Circuit pack removed or
SAKI Test (#53)
MIN/
WRN
2
ON
2 (b)
18 (c) 0 busyout board UUCSS WRN OFF release board UUCSS
23 (d) 0 WRN OFF add ds1 UUCSS
125 (e) none 3 None MIN/
WRN
3
ON
257 65535 Control Channel Loop
Test (#52)
MIN ON test board UUCSS l r 20
257 (f) Any None
513 (g) Any MIN/
WRN
3
ON
514 (h) 46086 MIN/
WRN
3
ON
769 (i) 46085 MIN/
WRN
3
ON
770 (j) 46096 MIN/
WRN
3
ON
1025 (d) 4363 NPE Audit Test (#50)
1281 Any Loss of Signal Alarm
Inquiry Test (#138)
MIN/
WRN
3
OFF test board UUCSS
1537 (k) 46082 MIN/
WRN
3
ON
1538 (l) Any MIN/
WRN
3
ON
1793 Any Blue Alarm Inquiry Test
(#139)
MAJ/
MIN/
WRN
4
OFF test board UUCSS
2049 Any Red Alarm Inquiry Test
(#140)
MIN/WR
N
3
OFF test board UUCSS
2305 Any Yellow Alarm Inquiry Test
(#141)
MIN/
WRN
3
OFF test board UUCSS
Continued on next page