DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Alarms, Errors, and Troubleshooting
5-42ATM Tips
5
It may be necessary to re-administer the A500 port boards. Refer to
the
Cajun A500 Quick Reference
for further information.
■ If
Admin Status
or
State
is incorrect, the links will not come up
between the PPN and the EPN.
TN230X
Did the TN230X come up correctly?
1. Review the LED conditions for the TN230X:
■ Do the TN230X LEDs (see Table 5-5) indicate a normal operational
state (any of the following):
— Active in the PPN
— Standby in the PPN
— Archangel mode in the EPN
— Standby in the EPN?
2. If after board insertion or a demand reset:
■ Do the TN230X LEDs indicate that it is booting?
■ Do the TN230X LEDs indicate it is downloading its DSPs?
■ Do the TN230X LEDs indicate that board insertion has not yet
occured?
■ Do the TN230X LEDs indicate a maintenance alarm?
3. Enter
list configuration carrier
cabinetcarrier
on the DEFINITY SAT. See
Figure 5-21
(1b) and
Figure 5-22
(2a) below.