9-1458SNI-BD (SNI Circuit Pack)
9
102 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 2.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 1, replace the SNI being
tested. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. To view SNI-PEER errors,
use the display errors command with category PNC-PEER. Retry the
command.
3. If the SNI being tested has SNI-PEER error type 1, replace the SNI in slot 2.
Replacing an SNI may be service interrupting. Refer to the SNI-BD section
for the procedure for replacing an SNI. Retry the command.
103 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 3.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 257, replace the SNI being
tested. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. To view SNI-PEER errors,
use the display errors command with category PNC-PEER. Retry the
command.
3. If the SNI being tested has SNI-PEER error type 257, replace the SNI in slot
3. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. Retry the command.
104 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 4.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 513, replace the SNI being
tested. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. To view SNI-PEER errors,
use the display errors command with category PNC-PEER. Retry the
command.
3. If the SNI being tested has SNI-PEER error type 513, replace the SNI in slot
4. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. Retry the command.
Table 9-562. TEST #759 Configuration Audit — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page