Maintenance Commands
8-204set options
8
Report
This option treats the alarms in the same way as the warning category with
one exception: alarms are reported to INADS using a special WARNING
category. When an alarm of this type is received, INADS logs the
occurrence and either creates a trouble ticket or closes it immediately. The
retry strategy for a call of this type is similar to normal Major or Minor alarm
reports. However, the acknowledgment LED on the attendant console or
alarm reporting station does not reflect the status of the call.
Ye s
Alarms are raised in the normal manner. There is no filtering of alarm data.
No
Alarms raised on a trunk, station, or adjunct in this category are dropped.
Error information is provided as before, but there is no trace of an alarm.
There is no LED activity and no call to INADS. Because resources are
taken out-of-service without any record, this option is recommended only
when other options do not provide the desired result.
The alarm options can be administered only on a system-wide basis for the
following alarm categories:
Major on-board station alarms
Minor on-board station alarms
Major off-board station alarms
Minor off-board station alarms
Four alarm severity groups are provided for trunk alarms. You can administer the
alarm options for the categories listed below in each alarm severity group.
However, in G1, the alarm options can be administered only on a system-wide
basis for the following categories:
Major on-board trunk alarms
Minor on-board trunk alarms
Major off-board trunk alarms
Minor off-board trunk alarms
For Adjuncts, an alarm severity option is assigned to each of the following
categories:
Major on-board adjunct alarms
Major off-board adjunct alarms
Minor on-board adjunct alarms
Minor off-board adjunct alarms