A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-733DUPINT (Duplication Interface Circuit Pack)
9
active and standby SPE carriers. Then, if all DUPINT and DUP-CHL alarms are
retired, a release of the standby SPE will allow memory shadowing to be turned
back on (if no further alarms pertinent to memory shadowing are present) and
refresh to complete. See STBY-SPE for more details as to how the turning on/off
of shadowing is controlled.
Error Log Entries and Test to Clear Values
Notes:
a. Indicates either a failure during a reset of the Duplication Interface circuit
pack, or a report that either or both of the HFAIL and STDONE bits are in
the wrong state. These errors cause a MINOR alarm that does not affect
memory shadowing. The Aux Data indicates which error occurred.
Table 9-281. Duplication Interface Circuit Pack Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
1
1. DUPINT alarms can be resolved only when the alarmed Duplication Interface circuit pack is in the
active SPE carrier.
On/Off
Board
Test to Clear
Value
0 0 Any Any Any
1 Control Register test (#865) MAJOR ON test dupl l
257 Any Mailbox Loop-around test (#866) MAJOR ON test dupl l
513 Any Local Loop-around test (#867) MAJOR ON test dupl l
769 Any Memory Shadowing Bounds Test
(#868)
MAJOR ON test dupl l
2049 (a) Any Active DUPINT Reset Test (#870)
Active DUPINT STDONE/ HFAIL Check
Test (#979)
MINOR ON test dupl l
3073 (b) 2 None MINOR ON test dupl l c
3329 (c) Any None MAJOR ON test dupl l c
Aux
Data Cause of Error
None The active DUPINT Reset Test failed because the reset was
unsuccessful.
1 The STDONE bit is in the wrong state.
2 The HFAIL bit is in the wrong state.
3 The STDONE and HFAIL bits are both in the wrong state.