DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-129list configuration
8
CSU MODThis field is displayed only when “list configuration ds1”
option is selected. The field contains the identification number of the
Integrated CSU module present on the ds1 circuit pack (TN767E or later /
TN464F or later) or “none”. If the circuit pack is a TN464E or TN767D,
“unknown” will be displayed. If the circuit pack is a TN464D or TN767C or
earlier suffix DS1 board, then “n/a” will be displayed.
Assigned Ports
Each port on the circuit pack is represented by a position corresponding to its
circuit number in ascending order from left to right. The assigned ports are not
displayed for
list configuration ds1
. Two rows are required for circuit packs with
more then 8 ports. The position displays one of the following values depending
on its administered status:
01-16The circuit number of an assigned port.
uThe port corresponding to this position exists but is unassigned.
tThe port is not currently assigned and is supported by the Terminal
Translation Initialization feature. Ports in this state can be activated by the
TTI association sequence.
mjThe port corresponding to this position is currently assigned as an
external device (mj) alarm port.
mnThe port corresponding to this position is currently assigned as an
external device (mn) alarm port.
Each port on a TN556 ISDN-BRI circuit pack can have two BRI endpoints. BRI
ports are displayed once when assigned only one endpoint and twice when fully
configured with two endpoints.