DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1442SNI-BD (SNI Circuit Pack)
9
102 FAIL The SNI circuit pack cannot communicate with the SNI in slot 2 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 2. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 1. If other SNI circuit packs have SNI-PEER error type
1, then replace the SNI in slot 2. Replacing an SNI may be service
interrupting. Refer to the SNI-BD section for the procedure for replacing an
SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 1 errors, the
problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 2.
103 FAIL The SNI circuit pack cannot communicate with the SNI in slot 3 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 3. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 257. If other SNI circuit packs have SNI-PEER error
type 257, then replace the SNI in slot 3. Replacing an SNI may be service
interrupting. Refer to the SNI-BD section for the procedure for replacing an
SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 257 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 3.
Table 9-559. TEST #755 SNI Circuit Path Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page