9
Error Log Entries and Test to Clear Values
Notes:
When problems persist, resetting the DS1 CONV circuit pack via the reset board
command may temporarily resolve the error condition and restore service until
further assistance is provided.
a. A major failure occurred on the DS1 interface hardware on the DS1 CONV
circuit pack associated with this DS1 facility. Replace the DS1 CONV
circuit pack.
Table 9-255. DS1 Facility Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test ds1-facility UUCSSf
sh r 1
1(a) Failure Audit #949 MAJOR ON test board UUCSS sh r 1
18(b) 0 busyout ds1-facility
UUCSSf
WARNING OFF release ds1-facility
UUCSS
257(c) Failure Audit #949 MINOR ON test board UUCSS sh r 1
513(d) 1 Failure Audit #949 MINOR OFF test board UUCSS sh r 1
513(d) 2 Failure Audit #949 MINOR OFF test board UUCSS sh r 1
856(e) DS1 Facility Query
for Slips/Misframes
#972
MINOR OFF none
1025(f) Failure Audit #949 MAJOR
2
2. These failures are logged as a WARNING alarm when the error is first reported. The alarm severity
is raised to a MAJOR in 15 minutes if the problem persists.
OFF test board UUCSS sh r 1
1281(g) None Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1281(g) 1 Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1281(g) 2 Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1537(h) Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1793(i) Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
2065(j) DS1 Facility Query
for Slips/Misframes
#972
MINOR OFF none
2305(k) Failure Audit #949 MAJOR OFF test board UUCSS sh r 1
2561(l) Failure Audit #949 MINOR
3
3. This failure is logged as a WARNING alarm when the error is first reported. The alarm severity is
raised to a MINOR in 15 minutes if the problem persists.
OFF test board UUCSS sh r 1