DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1449SNI-BD (SNI Circuit Pack)
9
119 FAIL The SNI circuit pack cannot communicate with the SNI in slot 19 over the
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 19. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 3585. If other SNI circuit packs have SNI-PEER error
type 3585, then replace the SNI in slot 19. Replacing an SNI may be
service interrupting. Refer to the SNI-BD section for the procedure for
replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 3385 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 19.
120 FAIL The SNI circuit pack cannot communicate with the SNI in slot 20 over the
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 20. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 3841. If other SNI circuit packs have SNI-PEER error
type 3841, then replace the SNI in slot 20. Replacing an SNI may be
service interrupting. Refer to the SNI-BD section for the procedure for
replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 3841 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 20.
Table 9-559. TEST #755 SNI Circuit Path Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page