DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-702DUP-CHL (Duplication Interface)
9
Once all DUPINT, DUP-CHL and any other alarms pertinent to shadowing are
retired, a release of the standby will allow shadowing to be turned back on and
refresh to complete. See STBY-SPE for more details.
DUP-CHL tests can also fail because shadowing is prevented by of a fault with
MO: PKT-INT or MEM-BD. Use the command
status spe
to observe the
presence of active alarms and display the alarm log to determine if alarms exist
against these related maintenance objects that could cause memory shadowing
to fail. MAJOR alarms from these other maintenance objects that cause memory
shadowing failures must be resolved before attempting to resolve DUP-CHL
alarms. A memory shadowing failure that is caused by another maintenance
object such as PKT-INT can also cause a DUP-CHL alarm due to a test failure or
in-line errors. Executing the
test duplication-interface long clear
command
after repairing the underlying cause of the memory shadowing failure can also
resolve a DUP-CHL alarm.
Error Log Entries and Test to Clear Values
Table 9-272. Duplication Channel Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
1
On/Off
Board Test to Clear Value
0
2
Any Any Any
001 State-of-Health (#873) MINOR ON test dupl l
257 Memory Shadow
Disable Interrupt test
(#872)
MINOR ON test dupl l
513 any SMM Channel test
(#874)
MINOR ON test dupl l
769 Remote Error Interrupt
test (#875)
MAJOR ON test dupl l
1025 Memory Shadowing test
(#876)
MAJOR ON test dupl l
1281(a) none MAJOR ON test dupl l c
1537(b) none MINOR ON test dupl l c
1793(c) none MAJOR ON test dupl l c
2049 Remote Loop-Around
test (#869)
MAJOR ON test dupl l
2305 FIFO Full Interrupt test
(#871)
MINOR ON test dupl l
Continued on next page